Home / Products / 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical
16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical
Switched PDU

16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical

Quick Answer16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  6. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  7. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • IEC and Schuko outlets on one 63 A switched strip
  • Sixteen positions for servers and European mains appliances
  • Per-outlet switching, metering and group thresholds
  • European racks often carry servers on C13 cords next to measurement gear, test units and small appliances on Schuko plugs. This strip serves both on one body: eight IEC positions and eight Schuko (Type F) outlets, fed through a 63 A hydraulic-magnetic breaker, with per-outlet switching and metering. Schuko positions are spaced wider so that moulded plugs and right-angle cords do not foul the neighbouring outlet, a detail that matters once sixteen cords are dressed into a 600 mm wide cabinet.

Frequently Asked Questions

What is the input connection of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

C13 / C19: ⁦⁦110–250⁩⁩ V AC; Schuko: ⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

63 A

What is the rated power of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

Up to 15 kW at 250 V

What is the monitoring interface of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet C13 C19 Schuko Switched Rack PDU, Vertical?

CE / EMC / RoHS; built under ISO 9001