Home / Products / 16-Outlet GB Switched Rack PDU, Vertical, 63 A
16-Outlet GB Switched Rack PDU, Vertical, 63 A
Switched PDU

16-Outlet GB Switched Rack PDU, Vertical, 63 A

Quick Answer16-Outlet GB Switched Rack PDU, Vertical, 63 A — an IDCPDU Switched PDU for remotely managed racks.
  1. Per-outlet remote switching — A hung node or miner is power-cycled from the control room in seconds — no trip to the rack, and nothing else on the strip goes dark.
  2. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  3. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  6. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  7. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Sixteen GB outlets on a vertical 1358 mm strip
  • Miniature circuit breaker feed, per-outlet switching
  • Full-length coverage of a 42U cabinet with one strip
  • Sixteen GB three-pin outlets spread over 1358 mm put a socket beside every shelf of a 42U cabinet, so no device needs an extension cord to reach power. The feed passes through a 63 A miniature circuit breaker at the head of the strip, and each outlet behind it switches and meters on its own. In a domestic data room or a branch office rack wired for GB plugs, this is the strip that replaces a row of socket strips and a pile of adapters.

Frequently Asked Questions

What is the input connection of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

Hard-wired terminal block, 5-wire

What is the input voltage of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

63 A

What is the rated power of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

Up to 15 kW at 250 V

What is the monitoring interface of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

TCP/IP, SNMP v1/v2/v3, Modbus TCP, RS485

What is the certification of 16-Outlet GB Switched Rack PDU, Vertical, 63 A?

CE / EMC / RoHS; built under ISO 9001

Related Products

← Back to Products