Home / Products / 19-Outlet IEC C13/C19 Vertical Rack PDU, 110–250 V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U
19-Outlet IEC C13/C19 Vertical Rack PDU, 110–250 V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U
Basic PDU

19-Outlet IEC C13/C19 Vertical Rack PDU, 110–250 V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U

Quick Answer19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  4. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 19 mixed IEC C13 and C19 outlets, 0U vertical
  • ⁦110–250⁩ V wide input, 63 A, C13 at 10 A, C19 at 16 A
  • Hydraulic breaker with three-lamp surge status
  • Servers on C13 and switches or blade chassis on C19 share one strip, so a rack no longer needs two separate PDUs per side. The 1358 mm body fits 42U rails on 60 × 85 mm section.
  • The three-lamp SPD shows L-N, L-E and N-E status separately, which tells an electrician whether the strip is seeing a phase fault or a neutral fault before anything is unplugged.
  • Chosen for mixed-load racks in enterprise data centres, edge sites and broadcast rooms where both C13 and C19 appliances sit in the same cabinet.
  • Outlet mix, cable length and plug type are built to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

What is the body dimensions (W×H) of 19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U?

60 × 85 mm

What is the max input current of 19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U?

63 A

What is the input voltage of 19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What input connection does the 19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U use?

OT terminal junction box

What is the certification of 19-Outlet IEC C13/C19 Vertical Rack PDU, ⁦110–250⁩ V 63 A, Hydraulic Breaker and 3-Lamp SPD, 0U?

CE / EMC; built under ISO 9001