Home / Products / 22-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Surge Protection, 0U
22-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Surge Protection, 0U
Basic PDU

22-Outlet GB Socket Vertical Rack PDU, 220–250 V 63 A, Surge Protection, 0U

Quick Answer22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U — an IDCPDU Basic PDU for data-centre and equipment-room racks.
  1. Local socket pattern, not an adapter job — Outlets are the pattern already installed in the building, so equipment cords go straight in — one joint less to loosen inside a live rack.
  2. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  3. 22 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • 22 GB sockets on a 0U vertical strip
  • ⁦220–250⁩ V, 63 A input, 10 A or 16 A outlets
  • Built-in surge protection with indicator
  • This is the distribution-only version: no breaker and no master switch, so the strip is isolated upstream at the panel or rack ATS. The 1358 mm body fits 42U rails.
  • Surge protection sits at the incoming end and protects all 22 outlets; the indicator shows whether the module is still live, which matters in sites fed by overhead lines.
  • Used where the rack already has upstream switching — colocation cages, telecom cabinets and factory IT racks on a switched busway.
  • Breaker, metering or master switch can be added to drawing: layout within 30 minutes, quotation within 1 hour.

Frequently Asked Questions

What is the body dimensions (W×H) of 22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U?

65 × 83 mm

What is the max input current of 22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U?

63 A

What is the input voltage of 22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What input connection does the 22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U use?

OT terminal junction box

What is the certification of 22-Outlet GB Socket Vertical Rack PDU, ⁦220–250⁩ V 63 A, Surge Protection, 0U?

CE / EMC; built under ISO 9001

Related Products