Quick AnswerIn-Row Liquid-to-Liquid CDU ⁦500–2000⁩ kW — an IDCPDU CDU for liquid-cooled high-density racks.
  1. Hot-swap pumps and filters — A pump or a filter is changed while the loop keeps running, so maintenance stops being a scheduled capacity outage.
  2. Capacity added unit by unit — Modules are paralleled as the hall fills, so capex follows the IT load instead of being committed up front.
  3. Rated for 24/7 duty — Continuous operation is the design case, not an overload condition — the loop is sized for heat that never stops.
  4. Filtration on the coolant side — The filters protect cold-plate micro-channels; one blocked channel is a hot GPU that no amount of airflow will fix.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • ⁦500–2000⁩ kW in-row CDU for direct-to-chip liquid cooling.
  • One unit covers a full row of high-density AI racks.
  • Liquid-to-liquid design isolates the IT loop from facility water.
  • Heat leaves the rack secondary loop through a plate heat exchanger and enters the facility chilled-water loop, so the two circuits never mix and the IT side stays clean. Because liquid carries far more heat per litre than air, the same footprint removes several times the load of a room-level air conditioner.
  • In typical direct-to-chip deployments PUE falls below 1.1 and cooling energy drops by up to 70% against air cooling, while the secondary supply stays above dew point, so no condensation forms on the manifolds.
  • Five capacities from 500 to 2,000 kW share a 2,000 mm height and 1,200 mm depth, so a row can be sized for today's load and extended later without re-piping the hall.
  • Pumps, filters and key components are hot-swappable, and the unit stands in-row beside the racks — no separate plant room and no ducting.

Frequently Asked Questions

What is the cooling capacity of In-Row Liquid-to-Liquid CDU ⁦500–2000⁩ kW?

500 / 800 / 1000 / 1500 / 2000 kW (five models)

What is the size (W×D×H) of In-Row Liquid-to-Liquid CDU ⁦500–2000⁩ kW?

⁦⁦600–1200⁩⁩ × 1200 × 2000 mm (by model)

Are you a direct manufacturer or a trading company?

IDCPDU is a direct manufacturer. We run our own factory and international sales department, with two casting foundries, one CNC machining factory and an in-house testing lab, so we produce and sell by ourselves.

What products does IDCPDU offer?

We focus on PDU, intelligent PDU, metered PDU, switched PDU, mining PDU, ATS, server rack cabinets and new energy vehicle charging boxes and distribution units.

Related Products

← Back to Products