Home / Products / Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A
Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A
Mining PDU

Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A

Quick AnswerMining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A — an IDCPDU Mining PDU for mining farms and hash centres.
  1. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  2. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  3. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  4. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.
  5. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.
  6. ⁦7–15⁩ working days after drawing approval — The clock starts when the drawing is signed off, and 30-minute proposals / 1-hour quotations come before that.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Ten C13 and C19 outlets over three phases
  • Hydraulic-magnetic breaker plus separate overload switch
  • An 881 mm body for half-height and wall-mounted racks
  • Not every mining cabinet is a 42U row. This 881 mm strip fits half-height racks, wall cabinets and the short frames used for control gear beside a hall, and still takes a three-phase 63 A feed split across L1, L2 and L3. A hydraulic-magnetic breaker handles the ambient heat without the thermal derating of a miniature breaker, and a separate overload switch gives a local trip and a visible reset point at the strip rather than back at the panel. C13 positions take the miner supplies, C19 positions take the bigger single feeds, and the 62 × 63 mm body leaves the rear channel clear.

Frequently Asked Questions

What is the body dimensions (W×H) of Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A?

62 × 63 mm

What input connection does the Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A use?

OT terminal junction box

What is the input voltage of Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A?

380 V AC three-phase (⁦⁦220–250⁩⁩ V phase to neutral), 50/60 Hz

What is the max input current of Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A?

63 A per phase

What is the certification of Mining Rack PDU 10-Outlet C13 C19, 3-Phase 63 A?

CE / EMC; built under ISO 9001