Home / Products / Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A
Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A
Mining PDU

Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A

Quick AnswerMining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A — an IDCPDU Mining PDU for mining farms and hash centres.
  1. 27 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  2. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  3. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  4. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  5. Passive build, nothing to fail — No metering board and no switching relay inside — for a basic strip that means fewer parts that can take a rack down.
  6. Built to drawing, not to a catalogue — Outlet mix, cable length and plug are set per order — sample-grade customisation without a tooling charge.
  7. ⁦7–15⁩ working days after drawing approval — The clock starts when the drawing is signed off, and 30-minute proposals / 1-hour quotations come before that.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Twenty-seven C13 and C19 outlets on a 180 mm body
  • 160 A per phase into L1 L2 L3 N barrier terminals
  • For a whole rack of machines behind one feed
  • When the row feed is already 160 A per phase, the strip has to be able to take it, and a standard 60 mm body cannot. This one is built on a 180 mm section with barrier terminals for L1, L2, L3 and N plus a separate earth stud, so a 160 A five-core cable lands without adapters. Twenty-seven outlets spread across the three phases feed the rack directly: C19 positions for the supplies that draw the most, C13 positions for the rest, all downstream of one 3-pole hydraulic-magnetic breaker that isolates the strip for service. The blue housing is a deliberate choice as much as a colour: it separates high-current mining distribution from ordinary IT strips in a mixed plant room.

Frequently Asked Questions

What is the input connection of Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A?

L1 / L2 / L3 / N barrier terminals

What is the input voltage of Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A?

380 V AC three-phase (⁦⁦220–250⁩⁩ V phase to neutral), 50/60 Hz

What is the max input current of Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A?

160 A per phase

What is the certification of Mining Rack PDU 27-Outlet C13 C19, 3-Phase 160 A?

CE / EMC; built under ISO 9001