Home / Products / Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered
Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered
Mining PDU

Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered

Quick AnswerMining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered — an IDCPDU Mining PDU for mining farms and hash centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. Lockable IEC sockets — C13 and C19 cords click in and stay in — vibration, cleaning and a stray knee no longer turn into an unexplained reboot.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Sixteen lockable C13 and C19 outlets on hot-swap modules
  • Per-port metering, Modbus-RTU over RS485
  • For racks that are re-cabled every week
  • A mining rack gets re-cabled every time a card or a power supply is swapped, and a plain C13 plug works loose after a few of those cycles. The outlets here are lockable modules that clip the cord in place, and each module unclips from the 2.5U body for replacement without taking the strip out of the rack. Metering is per port as well as total, read over RS485 Modbus-RTU or the network port, so a supply drawing more than its neighbours shows up before it fails. Surge protection sits at the inlet, and the sequential power-on function spreads inrush across the row instead of tripping the upstream breaker.

Frequently Asked Questions

What is the input connection of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

Hard-wired terminal block, 5-wire

What is the input voltage of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

16 A (32 A version to order)

What is the rated power of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

TCP/IP + RS485 Modbus-RTU

What is the certification of Mining Rack PDU 16-Outlet C13 C19 Lockable, 2.5U Metered?

CE / EMC / RoHS; built under ISO 9001