Home / Products / 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U
20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U
Metered PDU

20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U

Quick Answer20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. 20 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Networked 0U meter strip for 20 C13/C19 outlets, 63 A input
  • TCP/IP and environmental sensor report load, temperature and humidity
  • 1358 mm mounting length fits 42U to 47U cabinets
  • The inlet takes a 63 A feed through an OT terminal junction box, which covers a full 42U cabinet of blade servers on one strip without a second drop. The network card serves a web page and SNMP, and the sensor port carries temperature and humidity so hot spots are caught before they trip a server. Branch protection is hydraulic magnetic, immune to the thermal drift that nuisance-trips MCBs in warm cabinets.

Frequently Asked Questions

What is the body dimensions (W×H) of 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U?

60 × 85 mm

What input connection does the 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U use?

OT terminal junction box

What is the input voltage of 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U?

63 A

What is the rated power of 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U?

Up to 15 kW at 250 V

What is the monitoring interface of 20-Outlet C13/C19 Metered Rack PDU, TCP/IP Sensor, 63 A Input, 0U?

TCP/IP + RS485 Modbus-RTU