Home / Products / 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD
20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD
Metered PDU

20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD

Quick Answer20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Surge clamped before the power supplies — Lightning and switching surges are discharged at the strip; the status lamp shows when the cartridge is spent instead of failing silently.
  3. 20 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. Lockable IEC sockets — C13 and C19 cords click in and stay in — vibration, cleaning and a stray knee no longer turn into an unexplained reboot.
  6. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  7. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Vertical 1.5U metered strip for 20 C13/C19 loads in a 19-inch rack
  • Hot-swap meter reads total current, voltage, power and energy without shutdown
  • RS485 Modbus-RTU links up to several slave strips to one master
  • The 20 lockable outlets hold C13 and C19 cords in place on both single-phase 16 A and 32 A feeds, and the meter bay can be swapped while the rack keeps running. Surge protection is monitored, so a spent cartridge raises an alarm instead of failing silently. Order the socket mix, cord length and plug type to your drawing.

Frequently Asked Questions

What input connection does the 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD use?

Hard-wired terminal block

What is the input voltage of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

16 A (32 A version to order)

What is the rated power of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

RS485 Modbus-RTU

What is the certification of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1.5U Vertical, Hot-Swap Meter, RS485, SPD?

CE / EMC / RoHS; built under ISO 9001