Home / Products / 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485
20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485
Metered PDU

20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485

Quick Answer20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485 — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. 20 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  3. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  4. Lockable IEC sockets — C13 and C19 cords click in and stay in — vibration, cleaning and a stray knee no longer turn into an unexplained reboot.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Slim 1U metered strip for 20 C13/C19 loads in a 19-inch rack
  • Hot-swap meter with load indicator shows total current, voltage, power and energy
  • RS485 Modbus-RTU daisy-chains several strips to one master
  • The same 20 lockable outlets as the 1.5U model sit in a narrower 1U body, which suits racks with shallow rear clearance where a deeper section would foul the door or the cable tray. Every outlet carries a load indicator, so a tripped or unplugged circuit is visible at the rack without opening a browser. Metering stays at the inlet, so no per-outlet switching is involved.

Frequently Asked Questions

What input connection does the 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485 use?

Hard-wired terminal block

What is the input voltage of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485?

⁦⁦220–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485?

16 A (32 A version to order)

What is the rated power of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485?

3.5 kW at 16 A; 7.0 kW at 32 A

What is the monitoring interface of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485?

RS485 Modbus-RTU

What is the certification of 20-Outlet C13/C19 Lockable Metered Rack PDU, 1U Vertical, Hot-Swap Meter, RS485?

CE / EMC / RoHS; built under ISO 9001