24-Outlet C13/C19 Metered Rack PDU, 380–415 V, 32 A Industrial Plug, 0U
Metered PDU

24-Outlet C13/C19 Metered Rack PDU, 380–415 V, 32 A Industrial Plug, 0U

Quick Answer24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Three-phase feed, load spread over L1/L2/L3 — The rack is not hung on one leg, and the 23 kW envelope matches GPU, blade and miner density.
  3. 24 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  6. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  7. Field-standard input plug — Terminated with the connector electricians on site already stock, so commissioning does not wait for an adapter.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Vertical 24-outlet metered strip with a 32 A five-pin industrial plug
  • ⁦380–415⁩ V three-phase input, no hard wiring required on site
  • Per-group thresholds with local overload protection
  • The five-pin IEC 60309 plug lets the strip be connected and disconnected at the rack, which suits rented space, temporary builds and containers where hard wiring needs an electrician. Twenty-four C13/C19 outlets share the three phases, and current, voltage, power and energy are reported on the panel. Overload protection trips the strip before the upstream breaker takes the whole row down.

Frequently Asked Questions

What is the input connection of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

IEC 60309 32 A five-pin plug

What is the input voltage of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

⁦⁦380–415⁩⁩ V AC three-phase, 50/60 Hz

What is the max input current of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

32 A per phase

What is the rated power of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

Up to 23 kW at 415 V

What is the monitoring interface of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

RS485 Modbus-RTU

What is the certification of 24-Outlet C13/C19 Metered Rack PDU, ⁦380–415⁩ V, 32 A Industrial Plug, 0U?

CE / EMC / RoHS; built under ISO 9001