Home / Products / 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, 380–415 V
24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, 380–415 V
Metered PDU

24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, 380–415 V

Quick Answer24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Three-phase feed, load spread over L1/L2/L3 — The rack is not hung on one leg, and the 70 kW envelope matches GPU, blade and miner density.
  3. 24 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. 0U vertical — no rack units consumed — The strip hangs on the rear post, so every U stays available for servers.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  6. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  7. Runs below zero — Tested from sub-zero ambient upward, so cold shelters and unheated halls are inside the envelope, not outside it.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • High-power three-phase strip with 24 C19 outlets on a 125 A feed
  • 70 kW capacity for GPU servers, blade chassis and hash containers
  • Per-phase metering, group thresholds and over-current protection
  • Twenty-four C19 outlets are grouped eight per phase, so each L1, L2 and L3 branch feeds its own bank of high-draw equipment. The 125 A inlet and 70 kW rating suit GPU nodes and blade chassis that pull 3 kW to 6 kW per shelf, where a C13 strip would run out of outlets before it ran out of current. Current, voltage, power and energy are shown per phase on the LCD, and thresholds can be set per group.

Frequently Asked Questions

What is the input connection of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

Hard-wired terminal block, 5-wire

What is the input voltage of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

⁦⁦380–415⁩⁩ V AC three-phase, 50/60 Hz

What is the max input current of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

125 A per phase

What is the rated power of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

70 kW

What is the monitoring interface of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

RS485 Modbus-RTU

What is the certification of 24-Outlet C19 Metered Rack PDU, 125 A Three-Phase, 70 kW, ⁦380–415⁩ V?

CE / EMC / RoHS; built under ISO 9001