Home / Products / 36-Outlet C13/C19 Metered Rack PDU, 32 A, 110–250 V, 8 kW, Horizontal
36-Outlet C13/C19 Metered Rack PDU, 32 A, 110–250 V, 8 kW, Horizontal
Metered PDU

36-Outlet C13/C19 Metered Rack PDU, 32 A, 110–250 V, 8 kW, Horizontal

Quick Answer36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. 36 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  3. ⁦110–250⁩ V wide input — One build covers 120 V and 230 V sites and rides out a brownout instead of dropping the load.
  4. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  6. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  7. Anodised aluminium body — Lighter than a steel shell and it sheds heat instead of trapping it; there is no paint layer to chip during installation.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Horizontal metered strip with 36 C13 and 4 C19 outlets on one 32 A feed
  • 8 kW single-phase capacity at ⁦110–250⁩ V
  • Full-width bar reads output at the panel without opening a browser
  • Thirty-six C13 outlets cover a 42U cabinet of 1U servers, and the four C19 positions take switches, PDUs and storage shelves that ship with C20 cords. The bar mounts horizontally at the top or bottom of the rack, which keeps the vertical rails free for cable management. Current, voltage, power and energy are shown on the panel meter.

Frequently Asked Questions

What input connection does the 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal use?

Hard-wired terminal block

What is the input voltage of 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal?

⁦⁦110–250⁩⁩ V AC, 50/60 Hz

What is the max input current of 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal?

32 A

What is the rated power of 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal?

8 kW at 250 V

What is the monitoring interface of 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal?

RS485 Modbus-RTU

What is the certification of 36-Outlet C13/C19 Metered Rack PDU, 32 A, ⁦110–250⁩ V, 8 kW, Horizontal?

CE / EMC / RoHS; built under ISO 9001