36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, 380–415 V, 23 kW
Metered PDU

36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, 380–415 V, 23 kW

Quick Answer36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW — an IDCPDU Metered PDU for metered racks in data centres.
  1. Power read where it is consumed — Current, voltage, power and energy at the strip, shown on the local display and readable remotely — you spot a rack running out of headroom before the breaker trips.
  2. Three-phase feed, load spread over L1/L2/L3 — The rack is not hung on one leg, and the 23 kW envelope matches GPU, blade and miner density.
  3. 36 outlets on one strip — A single strip feeds a whole rack, so adding a node no longer means a second PDU and a second feed cable.
  4. C13 and C19 side by side — Servers, switches and storage hang off one strip — no second PDU just because the C19 count did not match the drawing.
  5. Breaker ahead of the outlets — A fault trips inside the strip, not at the upstream panel — the rest of the row keeps serving traffic.
  6. Hard-wired terminal block — There is no inlet plug to work loose or heat up — the feed lands on terminals sized for the strip's full current.
  7. Anodised aluminium body — Lighter than a steel shell and it sheds heat instead of trapping it; there is no paint layer to chip during installation.

Tel: +86-574-63783045 · ricky@idcpdu.com

Contact Us
SHARE:

Product Description

  • Three-phase horizontal strip with 36 C13 and 6 C19 outlets
  • 23 kW on a 32 A per-phase feed at ⁦380–415⁩ V
  • Per-phase metering on a full-width bar
  • The three-phase inlet lifts the same 36-outlet layout from 8 kW to 23 kW, which is what a GPU or dense compute cabinet actually draws. Six C19 positions take the C20 cords that come with switches, UPS outlets and storage shelves. Current is shown per phase on the panel, so an unbalanced cabinet is visible at the rack rather than at the upstream breaker.

Frequently Asked Questions

What is the input connection of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

Hard-wired terminal block, 5-wire

What is the input voltage of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

⁦⁦380–415⁩⁩ V AC three-phase, 50/60 Hz

What is the max input current of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

32 A per phase

What is the rated power of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

Up to 23 kW at 415 V

What is the monitoring interface of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

RS485 Modbus-RTU

What is the certification of 36-Outlet C13/C19 Metered Rack PDU, Three-Phase 32 A, ⁦380–415⁩ V, 23 kW?

CE / EMC / RoHS; built under ISO 9001